MOXA – INJ-24 – PoE Injector, maximum output of 30 W at 2448 VDC, 0 to 60C operating temperature

Brand:

246,63 

PoE+ Injector, maximum output of 30 W at 24/48 VDC, 0 to 60°C operating temperatureEthernet Interface10/100/1000BaseT(X) Ports (RJ45 connector)- 1- Full/Half duplex mode- Auto MDI/MDI-X connection- Auto negotiation speedPoE Ports (10/100/1000BaseT(X),…

When you purchase this item you will receive. 246 Points
Bulk PriceQuantity (from)Quantity (to)
246,63  1 19
218,22  20 49
216,32  50 199
214,42  200
Delivery time: 15-17 Workdays
SKU 387490
EAN 4251876864487
MPN INJ-24
Categories , ,
Tags , ,

PoE+ Injector, maximum output of 30 W at 24/48 VDC, 0 to 60°C operating temperature

Ethernet Interface

10/100/1000BaseT(X) Ports (RJ45 connector)
– 1
– Full/Half duplex mode
– Auto MDI/MDI-X connection
– Auto negotiation speed
PoE Ports (10/100/1000BaseT(X), RJ45 connector)
– 1
– Full/Half duplex mode
– Auto MDI/MDI-X connection
– Auto negotiation speed
PoE Pinout
– V+, V+, V-, V-, for pins 4, 5, 7, 8 (Midspan, MDI, Mode B)
Standards
– IEEE 802.3 for 10BaseT
– IEEE 802.3u for 100BaseT(X)
– IEEE 802.3ab for 1000BaseT(X)
– IEEE 802.3af/at for PoE/PoE+ output

Power Parameters

Input Voltage
– 24/48 VDC
Operating Voltage
– 22 to 57 VDC
Input Current
– 1.42 A @ 24 VDC
Power Consumption (Max.)
– Max. 4.08 W full loading without PDs’ consumption
Power Budget
– Max. 30 W for total PD consumption
– Max. 30 W for each PoE port
Connection
– 1 removable 3-contact terminal block(s)
Overload Current Protection
– Supported
Reverse Polarity Protection
– Supported

Physical Characteristics

Housing
– Plastic
IP Rating
– IP30
Dimensions
– 24.9 x 100 x 86.2 mm (0.98 x 3.93 x 3.39 in)
Weight
– 115 g (0.26 lb)
Installation
– DIN-rail mounting

Environmental Limits

Operating Temperature
– 0 to 60°C (32 to 140°F)
Storage Temperature (package included)
– -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
– 5 to 95% (non-condensing)

Standards and Certifications

Safety
– UL 508
– EN 62368-1
EMC
– EN 55032/24
EMI
– CISPR 32, FCC Part 15B Class A
EMS
– IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
– IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
– IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
– IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
– IEC 61000-4-6 CS: 10 V
– IEC 61000-4-8 PFMF
Freefall
– IEC 60068-2-31
Shock
– IEC 60068-2-27
Vibration
– IEC 60068-2-6

MTBF

Time
– 2,525,278 hrs
Standards
– Telcordia (Bellcore), GB