MOXA – MDR-60-24 – DIN-rail 24 VDC power supply with 60W2.5A, 85 to 264 VAC, or 120 to 370 VDC inpu

Brand:

119,64 

Introduction The MDR Power Supply Series supports inrush current protection of 30 A at 115 VAC and 60 A at 230 VAC. The series has an operating temperature range of -20 to 70°C, which ensures suitability for operating in harsh environments. In…

When you purchase this item you will receive. 119 Points
Bulk PriceQuantity (from)Quantity (to)
119,64  1 19
105,86  20 49
104,94  50 199
104,02  200 ∞
Delivery time: 17-19 Workdays
SKU 385765
EAN 4251877394594
MPN MDR-60-24
Categories , ,
Tags , ,

Introduction
The MDR Power Supply Series supports inrush current protection of 30 A at 115 VAC and 60 A at 230 VAC. The series has an operating temperature range of -20 to 70°C, which ensures suitability for operating in harsh environments. In addition, the MDR Series has passed a 100% full load burn-in test, is UL/CUL listed, TÜV/CB certified, and CE marked. There are also models available with output ratings from 40 W to 60 W with 24 VDC output.

Output Power Parameters
– Wattage: MDR-40-24: 40 W, MDR-60-24: 60 W
– Voltage: 24 VDC
– Current Rating: MDR-40-24: 0 to 1.7 A, MDR-60-24: 0 to 2.5 A
– Ripple and Noise: 150 mVp-p
– Voltage Adjustment Range: 24 to 30 VDC
– Setup/Rise Time at Full Load: 500 ms, 30 ms at 115 VAC, 500 ms, 30 ms at 230 VAC
– Typical Hold Up Time at Full Load: 20 ms at 115 VAC, 50 ms at 230 VAC

Input Power Parameters
– Voltage Range: 85 to 264 VAC (47 to 63 Hz), 120 to 370 VDC
– Typical Efficiency: 88%

Typical Current:
– MDR-40-24: 0.7 A @ 230 VAC, 1.1 A @ 115 VAC
– MDR-60-24: 1.0 A @ 230 VAC, 1.8 A @ 115 VAC

– Typical Current (cold start): 60 A @ 230 VAC, 30 A @ 115 VAC

Overload Protection
– Rated Output Power: 105 to 150%
– Protection Type: Constant current limiting, recovers automatically after fault condition is removed

Overvoltage Protection
– Overvoltage Range: 31.2 to 36 V
– Protection Type: Shut down operating voltage, repower on to recover

Physical Characteristics
– Dimensions: 40 x 90 x 100 mm (1.57 x 3.54 x 3.94 in)
– Weight: MDR-40-24: 260 g (0.57 lb), MDR-60-24: 280 g (0.62 lb)

Environmental Limits
– Operating Temperature: -20 to 70°C (-4 to 158°F)
– Max. Operating Temperature at Full Load: MDR-40-24: 60°C, MDR-60-24: 55°C
– Ambient Relative Humidity: 20 to 90% (non-condensing)

Standards and Certifications
– Safety: UL 508, EN 62368-1, IEC 62368-1

EMC:
– EN 55032/35
– EN 61000-3-2 Class A
– EN 61000-3-3
– EN IEC 61204-3
– EN IEC 61000-6-2

EMS:
– IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
– IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
– IEC 61000-4-4 EFT: Power: 2 kV
– IEC 61000-4-5 Surge: Power: 4 kV
– IEC 61000-4-6 CS: 0.15 kHz to 80 MHz: 10 Vrms
– IEC 61000-4-8 PFMF: 30 A/m
– IEC 61000-4-11

Weight 0,3 kg
Dimensions 10 × 9 × 4 cm
output power

60W

suitable for ...

MOXA

Produkttyp

power cable

Output voltage

24V

Color

multicolor

input voltage

110-230V

Product safety

Manufacturer information

VARIA System GmbH
Dr.-Salvador-Allende-Straße 191
09119 Chemnitz
DE - Deutschland

E-Mail: info@varia.org

Person responsible for the EU

VARIA System GmbH
Dr.-Salvador-Allende-Straße 191
09119 Chemnitz
DE - Deutschland

E-Mail: info@varia.org

Brand:

Moxa Inc is one of the three largest manufacturers of network solutions for industrial automation worldwide. Moxa's products are of reliable quality and are used in a wide variety of industries. The products are RoHS & WEEE compliant.