EDS-408A-2M1S-SC-T - Entry-level managed Ethernet switch with 5 10100BaseT(X) ports, 2 100BaseFX mul...

Deliverytime: 19 - 21 working days (Mo-Fr) *
1.282,25 EUR
Key points at a glance:
Product Description
Moxa's Layer 2 managed switches feature industrial-grade reliability, network redundancy, and security features based on the IEC 62443 standard. We offer toughened, industry-specific products with multiple industry certifications, such as parts of the EN 50155 standard for rail applications, IEC 61850-3 for power automation systems, and NEMA TS2 for intelligent transportation systems.

Entry-level managed Ethernet switch with 5 10/100BaseT(X) ports, 2 100BaseFX multi-mode ports, 1 100BaseFX single-mode port with SC connectors, -40 to 75°C operating temperature

Ethernet Interface
- 10/100BaseT(X) Ports (RJ45 connector)
5
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
- 100BaseFX Ports (multi-mode SC connector) 2
- 100BaseFX Ports (single-mode SC connector) 1
- Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for Rapid Spanning Tree Protocol

Ethernet Software Features
- Filter
802.1Q VLAN
GMRP
GVRP
IGMP v1/v2
Port-based VLAN
- Industrial Protocols
EtherNet/IP
Modbus TCP
- Management
Back Pressure Flow Control
BOOTP
DHCP Option 66/67/82
DHCP Server/Client
Flow control
IPv4/IPv6
LLDP
Port Mirror
RARP
RMON
SMTP
SNMP Inform
SNMPv1/v2c/v3
Syslog
Telnet
TFTP
- MIB
Bridge MIB
Ethernet-like MIB
MIB-II
P-BRIDGE MIB
RMON MIB Groups 1, 2, 3, 9
RSTP MIB
- Redundancy Protocols
RSTP
STP
Turbo Chain
Turbo Ring v1/v2
- Time Management
NTP Server/Client
SNTP

Switch Properties
- IGMP Groups 256
- MAC Table Size 8 K
- Max. No. of VLANs 64
- Packet Buffer Size 1 Mbits
- Priority Queues 4
- VLAN ID Range VID 1 to 4094

Serial Interface
- Console Port RS-232 (TxD, RxD, GND), 10-pin RJ45 (115200, n, 8, 1)

DIP Switch Configuration
- Ethernet Interface Turbo Ring, Master, Coupler, Reserve

Input/Output Interface
- Alarm Contact Channels Relay output with current carrying capacity of 1 A @ 24 VDC

Power Parameters
- Connection 1 removable 6-contact terminal block(s)
- Input Voltage
12/24/48 VDC
Redundant dual inputs
- Operating Voltage 9.6 to 60 VDC
- Input Current
0.73 @ 12 VDC
0.35 @ 24 VDC
0.18 @ 48 VDC
- Overload Current Protection Supported
- Reverse Polarity Protection Supported

Physical Characteristics
- Housing Metal
- IP Rating IP30
- Dimensions 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
- Weight 890 g (1.97 lb)
- Installation
DIN-rail mounting
Wall mounting (with optional kit)

Environmental Limits
- Operating Temperature -40 to 75°C (-40 to 167°F)
- Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity 5 to 95% (non-condensing)

Standards and Certifications
- Safety UL 508
- EMC EN 55032/35
- EMI CISPR 32, FCC Part 15B Class A
- EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
- Railway EN 50121-4
- Traffic Control EDS-408A, EDS-408A-MM-SC/MM-ST/SS-SC/EIP/PN models: NEMA TS2
- Vibration IEC 60068-2-6
- Shock IEC 60068-2-27
- Freefall IEC 60068-2-31

MTBF
- Time 1,253,072 hrs
- Standards Telcordia (Bellcore), GB
This website uses cookies to ensure you get the best user experience. Privacy Policy