86M-5212U-T - Module for the ioPAC 8600 series, 2-port 2-wire Ethernet switch
Railway, wind power and offshore applications require system reliability and stability, even in harsh environments. Our ruggedised controllers and I/O products are designed for use in extreme conditions and offer versatile data acquisition and control functions.
Module for the ioPAC 8600 series, 2-port 2-wire Ethernet switch, -40 to 75°C Operating temperature
Input/output interface
2-wire Ethernet ports
- 2
Isolation
- 3k VDC or 2k Vrms
Digital outputs
Connection
- Spring Euroblock-Terminal
I/O mode
- DO or PWM
Ethernet interface
Connection
- M12 D-coded 2-pin socket
Number of ports
- 2
Standards
- BroadR-Reach® for 10 Mbps and 100 Mbps
- IEEE 802.3 for 10BaseT
- IEEE 802.3u for 100BaseT(X) and 100BaseFX
Performance parameters
Power consumption
- 79.2 mA @ 24 VDC
Physical properties
Dimensions
- 25 x 128.2 x 85.5 mm (0.98 x 5.05 x 3.37 in)
Weight
- Less than 80 g
Cabling
- I/O cable, 16 to 28 AWG
Environmental conditions
Operating temperature
- -40 to 75°C (-40 to 167°F)
Storage temperature (in packaging)
- -40 to 85°C (-40 to 185°F)
Relative humidity
- 5 to 95% (non-condensing)
Altitude
- 2000 m
Standards and certifications
EMC
- EN 55032/24, EN 61000-6-2/-6-4
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
- IEC 61000-4-3 RS: 5100 MHz to 6000 MHz: 3 V/m
- IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
- IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
- IEC 61000-4-6 CS: 10 V
- IEC 61000-4-8 PFMF
Railway
- EN 50121-4, EN 50155
Safety
- UL 508
Shock
- IEC 60068-2-27
Vibration
- IEC 60068-2-6
MTBF
Time
- 2,498.942 hours
Standards
- Telcordia SR332