CB-114-T - PC104-Plus bus, 4-port RS-232422485 module

Deliverytime: 17 - 19 working days (Mo-Fr) *
392,95 EUR
Key points at a glance:
Product Description

Our wide range of industrial-grade PC/104 and PC/104-Plus serial cards is a popular choice for embedded applications requiring connections to multiple serial devices with high data throughput.

PC/104-Plus bus, 4-port RS-232/422/485 module, -40 to 85°C operating temperature

Serial interface
Comm. Controller
- 16C550C or compatible x 4
Bus
- PC/104-Plus bus
Connector
- 40-pin header
DIP switch
- Serial interface
IRQ
- Assigned by BIOS
I/O address
- Assigned by BIOS
FIFO
- 128 bytes
Max. Number of cards per PC
- 8
Number of ports
- 4
Serial standards
- RS-232, RS-422, RS-485
Baud rate
- 50 bps to 921.6 kbps
Data bits
- 5, 6, 7, 8
Stop bits
- 1, 1.5, 2
Parity
- None, Even, Odd, Space, Mark
Flow control
- None, RTS/CTS, XON/XOFF

Serial signals
RS-232
- TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
- Data+, Data-, GND

Serial software functions
Windows driver
- DOS, Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded
Linux drivers
- Linux kernel 2.4.x, Linux kernel 2.6.x, Linux kernel 3.x
UNIX driver
- QNX 6, Solaris 10, UnixWare 7

Performance parameters
Input current
- 164 mA @ 5 VDC
Input voltage
- 5 VDC

Physical properties
Dimensions
- 90 x 96 mm (3.54 x 3.78 in)

LED interface
LED indicators
- Built-in Tx, Rx LEDs for each port

Environmental conditions
Operating temperature
- -40 to 85°C (-40 to 185°F)
Storage temperature (in packaging)
- -40 to 85°C (-40 to 185°F)
Relative humidity
- 5 to 95% (non-condensing)

Standards and certifications
EMC
- EN 55032/24
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
- IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
- IEC 61000-4-5 Surge: Power: 0.5 kV
- IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
- IEC 61000-4-8 PFMF
Environmental tests
- IEC 60068-2-1
- IEC 60068-2-2
- IEC 60068-2-3
- IEC 60068-2-14
Vibration
- IEC 60068-2-6

Declaration
Environmentally friendly product
- RoHS, CRoHS, WEEE

MTBF
Time
- 381.081 hours
Standards
- Telcordia (Bellcore), GB

This website uses cookies to ensure you get the best user experience. Privacy Policy