IOLOGIK E1512-M12-T - Robust IO, 4 DIs, 4 DIOs, -40 to 85C operating temperature

Deliverytime: 19 - 21 working days (Mo-Fr) *
1.049,45 EUR
Key points at a glance:
Product Description

Railway, wind power and offshore applications require system reliability and stability, even in harsh environments. Our rugged controllers and I/O products are designed for use in extreme conditions while providing versatile data acquisition and control functions.

Robust I/O, 4 DIs, 4 DIOs, -40 to 85 °C operating temperature

Input/output interface
- Digital input channels 4
- Configurable DIO channels (via software) 4
- Isolation 3 kV VDC or 2 kVrms
- Buttons Reset button

Digital inputs
Connection spring terminal euroblock
Counter frequency 250 Hz
Digital filter time interval Configurable via software
Dry contact
On: Short circuit to GND
Off: Open
- I/O mode DI or event counter
- Points per COM 2 channels
- Sensor type
Dry contact
Wet contact (NPN or PNP)
- Wet contact (DI to GND)
On: 10 to 30 VDC
Off: 0 to 3 VDC

Digital outputs
- Connection spring terminal euroblock
- Rated current 200 mA per channel
- I/O mode DO or pulse output
- I/O type sink
- Overcurrent protection 0.65 A per channel at 25 °C
- Overtemperature cut-off 175 °C (typical), 150 °C (min.)
- Overvoltage protection 35 VDC
- Pulse output frequency 500 Hz

Ethernet interface
- 10/100BaseT(X) connections (M12 D-coded 4-pin female connector) 1
- Magnetic insulation protection 1,5 kV (built-in)

Ethernet software functions
- Configuration options
Web console (HTTP)
Windows utility (ioSearch)
- Industrial protocols
Modbus TCP-Server (Slave)
Moxa AOPC (Active Tag)
MXIO library
- Administration
BOOTP
DHCP client
HTTP
IPv4
TCP/IP
UDP

LED interface
- LED indicators PWR, RDY, EXP, LAN, DI channels, DO channels

Modbus TCP
- Server mode
- Supported functions 1, 2, 3, 4, 5, 6, 15, 16

Current parameters
- Power connection spring terminal euroblock
- Number of current inputs 1
- Input voltage 12 to 48 VDC
- Current consumption 150 mA at 24 VDC

Physical properties
- Housing aluminium
- Dimensions 144 x 124 x 30 mm (5,67 x 4.88 x 1.18 inches)
- Weight 825 g (1.82 lb)
- Installation DIN rail mount
- Wall mount (with optional kit) Cabling
- I/O cable, 16 to 26 AWG Power cable, 16 to 26 AWG

Environmental limits
- Relative humidity 5 to 95% (non-condensing)
- Altitude 2000 m
- Storage temperature -40 to 85°C (-40 to 185°F)
- Storage temperature (included) -40 to 85°C (-40 to 185°F)

Standards and certifications
- EMC EN 61000-6-2/-6-4
- EMI CISPR 32, FCC Part 15B Class A
- EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Overvoltage: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
- Railway
EN 50121-4
EN 50155
- Safety UL 508
- Shock IEC 60068-2-27
- Vibration IEC 60068-2-6

Declaration
- Environmentally friendly product RoHS, CRoHS, WEEE

MTBF
- Time 554.122 hrs
- Standards Telcordia SR332

This website uses cookies to ensure you get the best user experience. Privacy Policy