IOLOGIK R1214-T - Universal IO, 6 DIs, 6 relays, -40 to 85C operating temperature

Deliverytime: 17 - 19 working days (Mo-Fr) *
330,29 EUR
Key points at a glance:
Product Description
Our universal controllers and I/O products use Click&Go control logic, which includes our active monitoring technology and support for a versatile set of OT/IT protocols, to help you easily configure, deploy, and realize IIoT applications such as energy monitoring, facility monitoring, and machine OEM applications.

Universal I/O, 6 DIs, 6 relays, -40 to 85°C operating temperature

Input/Output Interface
Buttons
- Reset button
Digital Input Channels
- 6
Isolation
- 3k VDC or 2k Vrms
Relay Channels
- 6

Digital Inputs
Connector
- Screw-fastened Euroblock terminal
Counter Frequency
- 2.5 kHz
Digital Filtering Time Interval
- Software configurable
Dry Contact
- On: short to GND
- Off: open
I/O Mode
- DI or event counter
Points per COM
- 6 channels
Sensor Type
- Dry contact
- Wet Contact (NPN or PNP)
Wet Contact (DI to COM)
- On: 10 to 30 VDC
- Off: 0 to 3 VDC

Relays
Breakdown Voltage
- 500 VAC
Connector
- Screw-fastened Euroblock terminal
Contact Current Rating
- Resistive load: 5 A @ 30 VDC, 250 VAC, 110 VAC
Contact Resistance
- 100 milli-ohms (max.)
Electrical Endurance
- 100,000 operations @ 5 A resistive load
Initial Insulation Resistance
- 1,000 mega-ohms (min.) @ 500 VDC
Mechanical Endurance
- 5,000,000 operations
Pulse Output Frequency
- 0.3 Hz at rated load
Type
- Form A (N.O.) power relay
Note
- Ambient humidity must be non-condensing and remain between 5 and 95%. The relays may malfunction when operating in high condensation environments below 0°C.

LED Interface
LED Indicators
- PWR, RDY, P1, P2

Serial Interface
Baudrate
- 1200 bps to 921.6 kbps
Connector
- Terminal block
No. of Ports
- 2
Parity
- None
- Even
- Odd
Pull High/Low Resistor for RS-485
- 1 kilo-ohm, 150 kilo-ohms
Serial Standards
- RS-485
Stop Bits
- 1, 2
Surge
- 1 kV
ESD
- 15 kV
Data Bits
- 8
Flow Control
- None
- XON/XOFF

Serial Signals
RS-485-2w
- Data+, Data-, GND

Serial Software Features
Industrial Protocols
- Modbus RTU Server (slave)

Power Parameters
Power Connector
- Screw-fastened Euroblock terminal
No. of Power Inputs
- 1
Input Voltage
- 12 to 48 VDC
Power Consumption
- 207 mA @ 24 VDC

Physical Characteristics
Housing
- Plastic
Dimensions
- 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
Weight
- 200 g (0.44 lb)
Installation
- DIN-rail mounting
- Wall mounting
Wiring
- I/O cable, 16 to 26 AWG
- Power cable, 12 to 24 AWG

Environmental Limits
Operating Temperature
- -40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
- 5 to 95% (non-condensing)
Altitude
- 2000 m

Standards and Certifications
EMC
- EN 55032/24
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
- IEC 61000-4-4 EFT: Power: 0.5 kV
- IEC 61000-4-5 Surge: Power: 2 kV
- IEC 61000-4-6 CS: 3 V
- IEC 61000-4-8 PFMF
Safety
- UL 508
Shock
- IEC 60068-2-27
Vibration
- IEC 60068-2-6

Declaration
Green Product
- RoHS, CRoHS, WEEE

MTBF
Time
- 1,239,293 hrs
Standards
- Telcordia SR332
This website uses cookies to ensure you get the best user experience. Privacy Policy