Key points at a glance:
Product Description

Moxa is an IRIS-certified company that offers an extensive portfolio of robust Ethernet switches that fulfil the mandatory sections of the EN 50155 standard. These products are used in many railway and metro systems around the world. With our innovative solutions and technologies, we help train builders to increase overall traffic safety and efficiency as well as achieve significant cost and time savings in the operation and maintenance of railway vehicles.

Unmanaged Ethernet switch with 8 10/100BaseT(X) ports with M12 connectors, 7 to 60 VDC, -40 to 75°C operating temperature, M12 power cable

Ethernet Interface
- 10/100BaseT(X) ports (M12 D-coded 4-pin female connector) 8
- Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for flow control

Power Parameters
- Input Current 0.19 A @ 12 VDC, 0.10 A @ 24 VDC, 0.054 A @ 48 VDC
- Input Voltage 12 to 48 VDC
- No. of Power Inputs 1
- Operating Voltage 8.4 to 60 VDC
- Power Connector M12 A-coded male connector

Physical Characteristics
- Housing Metal
- IP Rating IP40
- Dimensions 60 x 216.6 x 36.1 mm (2.36 x 8.53 x 1.42 in)
- Weight Packaged: 485 g (1.07 lb)
- Installation
DIN-rail mounting (with optional kit)
Wall mounting

Environmental Limits
- Operating Temperature -40 to 75°C (-40 to 167°F)
- Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity 5 to 95% (non-condensing)
- Altitude 2000 m

Standards and Certifications
- Freefall IEC 60068-2-32
- EMC EN 55032/35
- EMI CISPR 32, FCC Part 15B Class A
- EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
- Environmental Testing
IEC 60068-2-1, EN 50155
IEC 60068-2-14, EN 50155
IEC 60068-2-2, EN 50155
IEC 60068-2-30, EN 50155
- International Approval RCM
- Railway
EN 50121-4
EN 50155
- Railway Fire Protection EN 45545-2
- Safety
EN 60950-1
UL 508
- Salt Spray Test IEC 60068-2-11, EN 50155
- Shock IEC 60068-2-27, IEC 61373, EN 50155
- Vibration IEC 60068-2-64, IEC 61373, EN 50155

Declaration
- Green Product RoHS, CRoHS, WEEE

MTBF
- Time 2,804,342 hrs
- Standards Telcordia SR332