EDS-4008-4P-2GT-2GS-LVA - Managed Gigabit Ethernet switch with 4 10/100BaseT(X) ports
Managed Gigabit Ethernet switch with 4 10/100BaseT(X) ports with 802.3bt PoE, 2 10/100/1000BaseT(X), 2 100/1000BaseSFP ports, dual power supply 12/24/48 VDC, 48 VDC for PoE, -10 to 60°C operating temperature
Ethernet interface
PoE ports (10/100BaseT(X), RJ45 connection)
- 4
10/100/1000BaseT(X) ports (RJ45 connection)
- 2
100/1000BaseSFP slots
- 2
standards
- IEEE 802.3 for 10BaseT
- IEEE 802.3u for 100BaseT(X) and 100BaseFX
- IEEE 802.3ab for 1000BaseT(X)
- IEEE 802.3z for 1000BaseX
- IEEE 802.3x for flow control
- IEEE 802.3ad for Port Trunk with LACP
- IEEE 802.1Q for VLAN Tagging
- IEEE 802.1D-2004 for Spanning Tree Protocol
- IEEE 802.1w for Rapid Spanning Tree Protocol
- IEEE 802.1p for Class of Service
- IEEE 802.1X for authentication
Ethernet Software Features
Industrial Protocols
- EtherNet/IP
- Modbus TCP
- PROFINET IO Device
Management
- IPv4/IPv6
- Flow Control
- Back Pressure Flow Control
- DHCP Server/Client
- ARP
- RARP
- LLDP
- Fibre check
- Port Mirroring (SPAN, RSPAN)
- Linkup Delay
- SMTP
- SNMP Trap
- SNMP Inform
- SNMPv1/v2c/v3
- RMON
- TFTP
- SFTP
- HTTP
- HTTPS
- Telnet
- Syslog
- Private MIB
Filter
- GMRP
- GVRP
- GARP
- 802.1Q VLAN
- IGMP Snooping v1/v2/v3
- IGMP Querier
Redundancy Protocols
- STP
- RSTP
- Turbo Ring v2
- Turbo Chain
- Ring Coupling
- Dual-Homing
- Link Aggregation
- MSTP
- MRP
Security
- Broadcast Storm Protection
- Rate Limit
- Trust Access Control
- Static Port Lock
- MAC Sticky
- HTTPS/SSL
- SSH
- RADIUS
- TACACS+
- Access control list
- Login and Password Policy
- DHCP Snooping
Time Management
- SNTP
- NTP Server/Client
- NTP Authentication
- IEEE 1588v2 PTP (hardware-based)
- Supported stream profiles: IEEE 1588 Default 2008, IEC 61850-9-3-2016, IEEE C37.238-2017
Protocols
- IPv4/IPv6
- TCP/IP
- UDP
- ICMP
- ARP
- RARP
- TFTP
- DNS
- NTP Client
- DHCP Server
- DHCP Client
- 802.1X
- QoS
- HTTPS
- HTTP
- Telnet
- SMTP
- SNMPv1/v2c/v3
- RMON
- Syslog
MIB
- P-BRIDGE MIB
- Q-BRIDGE MIB
- IEEE8021-SPANNING-TREE-MIB
- IEEE8021-PAE-MIB
- IEEE8023-LAG-MIB
- LLDP-EXT-DOT1-MIB
- LLDP-EXT-DOT3-MIB
- SNMPv2-MIB
- RMON MIB Groups 1, 2, 3, 9
Switch Properties
MAC Table Size
- 16 K
Jumbo Frame Size
- 9.216 KB
Max. Number VLANs
- 256
VLAN ID Range
- VID 1 to 4094
IGMP Groups
- 512
Priority Queues
- 4
Packet Buffer Size
- 1 MB
LED Interface
LED Indicators
- PWR1, PWR2, STATE, FAULT, MSTR/HEAD, CPLR/TAIL, SYNC
Serial interface
Console connection
- RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
USB interface
USB port
- USB type A (reserved)
Input/output interface
Alarm contact channels
- 1, relay output with a current carrying capacity of 1 A @ 24 VDC
Digital input channels
- 1
Digital inputs
- +13 to +30 V for state 1
- -30 to +3 V for state 0
- Max. input current: 8 mA Keys Input current: 8 mA
Buttons
- Reset button
DIP switch configuration
DIP switch
- Turbo Ring, Master, Coupler, Reserve
Power parameters
Connection
- 2 removable 4-contact terminal block(s)
Pre-installed power module
- PWR-101-LV-BP-I
Note
- The EDS-4008 series supports modular power supplies. The model names and power parameters are determined by the installed power module.
Example:
EDS-4008-T + PWR-100-LV = EDS-4008-LV-T
EDS-4008-T + PWR-105-HV-I = EDS-4008-HV-T
If you install a different power module, observe the specifications of the corresponding
model. For example, if you replace the power module of the EDS-4008-LV-T
with the PWR-105-HV-I, observe the technical data of the EDS-4008-HV-T.
Input voltage
- 48 VDC
- Single input
Operating voltage
- 44 to 57 VDC (> 52 VDC recommended for PoE+ output)
Input current
- 48 VDC, 5.42 A
Power consumption (max.)
- Without PoE: 11.22 W
- With PoE: Max. 240 W for total PD power consumption at 48 VDC input
Max. PoE output power per port
- 90 W
Overload protection
- Supported
Reverse polarity protection
- Supported
Physical properties
IP protection class
- IP40
Dimensions
- 55 x 140 x 122.5 mm (2.17 x 5.51 x 4.82 in)
Weight
- 840 g (1.85 lb)
Installation
- DIN rail mounting
- Wall mounting (with optional kit)
Housing
- Metal
Environmental conditions
Operating temperature
- -10 to 60°C (14 to 140°F)
Storage temperature (including packaging)
- -40 to 85°C (-40 to 185°F)
Relative ambient humidity
- 5 to 95% (non-condensing)
Standards and certifications
Industrial cyber security
- IEC 62443-4-1
- IEC 62443-4-2
Safety
- UL 61010-2-201
- EN 62368-1 (LVD)
EMC
- EN 55032/35
- EN 61000-6-2/-6-4
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
- IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
- IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
- IEC 61000-4-6 CS: 10 V
- IEC 61000-4-8 PFMF
Marine
- ABS
- DNV
- NK
- LR
Vibration
- IEC 60068-2-6
Shock
- IEC 60068-2-27
Free fall
- IEC 60068-2-32
Railway
- EN 50121-4
Traffic control
- NEMA TS2
Substations
- IEC 61850-3
- IEEE 1613 Class 1
MTBF
Time
- 923,670 hours
Standards
- Telcordia SR332