EDS-G308-T - Unmanaged full Gigabit Ethernet switch with 8 10/100 1000BaseT(X) ports

Deliverytime: 9 - 11 working days (Mo-Fr) *
429,99 EUR
Key points at a glance:
Product Description

Unmanaged full Gigabit Ethernet switch with 8 10/100/1000BaseT(X) ports, Operating temperature from -40 to 75 °C

Input/output interface
Alarm contact channels
- 1 relay output with a current carrying capacity of 1 A @ 24 VDC

Ethernet interface
10/100/1000BaseT(X) ports (RJ45 connector)
- 8
- Speed with automatic negotiation
- Full/half-duplex mode
- Auto MDI/MDI-X connection
Standards
- IEEE 802.3 for 10BaseT
- IEEE 802.3ab for 1000BaseT(X)
- IEEE 802.3u for 100BaseT(X) and 100BaseFX
- IEEE 802.3x for flow control
- IEEE 802.3z for 1000BaseX
- IEEE 802.3az for energy-efficient Ethernet

DIP switch configuration
Ethernet interface
- Broadcast storm protection
- Jumbo frame
- IEEE 802.3az energy saving
- 100/1000 SFP speed switching
- Port break alarm

Switch properties
Jumbo frame size
- 9.6 KB
MAC Table Size
- 8 K
Packet Buffer Size
- 4 Mbits
Processing Type
- Store and Forward

Power Parameters
Connection
- 1 detachable 6-contact terminal block(s)
Input Voltage
- 12/24/48 VDC
- Redundant dual inputs
Operating Voltage
- 9.6 to 60 VDC
Reverse polarity protection
- Supported
Input current
- 0.8 A @ 12-48 VDC

Physical properties
Housing
- Metal
IP protection class
- IP30
Dimensions
- 52.85 x 135 x 105 mm (2.08 x 5.31 x 4.13 in)
Weight
- 880 g (1.94 lb)
Installation
- DIN rail mounting
- Wall mounting (with optional kit)

Ambient conditions
Operating temperature
- -40 to 75°C (-40 to 167°F)
Storage temperature (including packaging)
- - - -40 to 85°C (-40 to 185°F)
Relative humidity
- 5 to 95% (non-condensing)

Standards and certifications
Safety
- UL 508
- EN 62368-1 (LVD)
EMC
- EN 55032/35
- EN 61000-6-2/-6-4
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 800 MHz: 10 V/m
- IEC 61000-4-3 RS: 800 MHz to 1 GHz: 20 V/m
- IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-6 CS: 10 V
- IEC 61000-4-8 PFMF: 100 A/m
Hazardous areas
- ATEX
- Class I Division 2
Railway
- EN 50121-4
Vibration
- IEC 60068-2-6
Shock
- IEC 60068-2-27
Free fall
- IEC 60068-2-32
Maritime
- DNV
- LR
- ABS
- NK

MTBF
Time
- 2,398.736 hours
Standards
- Telcordia (Bellcore), GB