MGATE 5217I-1200-T - 2-port Modbus-to-BACnetIP gateway, 1200 points, 2kV isolation, 12 to 48 VDC, 24

Deliverytime: 9 - 11 working days (Mo-Fr) *
1.132,79 EUR
Key points at a glance:
Product Description
Whether single or multiple serial ports, Moxa’s Modbus TCP gateway solutions convert data in networks between Modbus RTU/ASCII, Modbus TCP, DNP3, CANopen, J1939, PROFIBUS, BACnet/IP, IEC 101/104, and IEC 61850, making configuration, troubleshooting, and conversion quick and easy.

2-port Modbus-to-BACnet/IP gateway, 1200 points, 2kV isolation, 12 to 48 VDC, 24 VAC, -40 to 75°C operating temperature

Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector)
- 2
- Auto MDI/MDI-X connection
Magnetic Isolation Protection
- 1.5 kV (built-in)

Ethernet Software Features
Industrial Protocols
- Modbus TCP Client (Master)
- BACnet/IP Server (Slave)
Configuration Options
- Web Console (HTTP/HTTPS)
- Device Search Utility (DSU)
- Telnet Console
Management
- ARP
- DHCP Client
- DNS
- HTTP
- HTTPS
- SMTP
- SNMP Trap
- SNMPv1/v2c/v3
- TCP/IP
- Telnet
- UDP
- NTP Client
MIB
- RFC1213, RFC1317
Time Management
- NTP Client

Security Functions
Authentication
- Local database
Encryption
- HTTPS
- AES-128
- AES-256
- SHA-256
Security Protocols
- SNMPv3
- SNMPv2c Trap
- HTTPS (TLS 1.2)

Serial Interface
No. of Ports
- 2
Connector
- DB9 male
Serial Standards
- RS-232/422/485
Baudrate
- 50 bps to 921.6 kbps
Data Bits
- 7, 8
Parity
- None
- Even
- Odd
- Space
- Mark
Stop Bits
- 1, 2
Flow Control
- RTS Toggle (RS-232 only)
- RTS/CTS
- DTR/DSR
RS-485 Data Direction Control
- Automatic Data Direction Control (ADDC)
Pull High/Low Resistor for RS-485
- 1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485
- 120 ohms
Isolation
- 2 kV (built-in)

Serial Signals
RS-232
- TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
- Data+, Data-, GND
RS-485-4w
- Tx+, Tx-, Rx+, Rx-, GND

Serial Software Features
Industrial Protocols
- Modbus RTU/ASCII Master

Modbus RTU/ASCII
Mode
- Master
Functions Supported
- 1, 2, 3, 4, 5, 6, 16
Max. No. of Commands
- 1200

Modbus TCP
Mode
- Client (Master)
Functions Supported
- 1, 2, 3, 4, 5, 6, 16
Max. No. of Server Connections
- 32
Max. No. of Commands
- 1200

BACnet/IP
Mode
- Server (Slave)
Memory Size
- 1200 points
Supported BACnet Object
- Binary Input
- Binary Output
- Binary Value
- Analog Input
- Analog Output
- Analog Value
- Multi-state Input
- Multi-state Output
- Multi-state Value
- Integer Value
- Positive Integer Value

Power Parameters
Input Voltage
- 24 VAC
- 12 to 48 VDC
Input Current
- 300 mA @ 24 VAC
- 510 mA @ 12 VDC
Power Connector
- Screw-fastened Euroblock terminal

Relays
Contact Current Rating
- Resistive load: 1 A @ 30 VDC

Physical Characteristics
Housing
- Plastic
IP Rating
- IP30
Dimensions (without ears)
- 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in)
Dimensions (with ears)
- 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in)
Weight
- 380 g (0.84 lb)

Environmental Limits
Operating Temperature
- -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
- 5 to 95% (non-condensing)

Standards and Certifications
EMC
- EN 55032/35
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
- IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
- IEC 61000-4-5 Surge: Power: 2 kV
- IEC 61000-4-6 CS: 10 V
- IEC 61000-4-8 PFMF
- IEC 61000-4-11
Safety
- UL 60950-1
- UL 62368-1
- IEC 60950-1
- IEC 62368-1
Freefall
- IEC 60068-2-32
Shock
- IEC 60068-2-27
Vibration
- IEC 60068-2-6
- IEC 60068-2-64
International Approval
- KC

MTBF
Time
- 1,277,500 hrs
Standards
- Telcordia SR332
This website uses cookies to ensure you get the best user experience. Privacy Policy