TN-5305 - Unmanaged IP67-certified Ethernet switch with 5 10100BaseT(X) ports with M12 connection
Moxa is an IRIS-certified company that offers an extensive portfolio of robust Ethernet switches that fulfil the mandatory sections of the EN 50155 standard. These products are used in many railway and metro systems around the world. With our innovative solutions and technologies, we help railway manufacturers to increase the safety and efficiency of all traffic and achieve significant cost and time savings in operation and maintenance.
Unmanaged IP67 Ethernet switch with 5 10/100BaseT(X) ports with M12 connectors, -25 to 60 °C operating temperature, M12 power cable
Ethernet interface
10/100BaseT(X) ports (M12 D-coded 4-pin socket)
- 5
Standards
- IEEE 802.3 for 10BaseT
- IEEE 802.3u for 100BaseT(X)
- IEEE 802.3x for flow control
Current parameters
Input current
- 0.1 A @ 24 VDC, 0,08 A @ 36 VDC
Input voltage
- 18 to 30 VAC (47 to 63 Hz)
- 24 to 36 VDC
Number of current inputs
- 1
Operating voltage
- 18 to 30 VAC
- 12 to 45 VDC
Power connection
- M12 A-coded plug
Physical properties
Housing
- Top cover made of plastic, Metal base plate
Protection class
- IP67
Dimensions
- 60 x 125 x 29.6 mm (2.36 x 4.92 x 1.09 in)
Weight
- Packed: 270 g (0.56 lb)
Installation
- DIN rail mounting (with optional kit)
- Wall mounting
Ambient conditions
Operating temperature
- -25 to 60°C (-13 to 140°F)
Storage temperature (including packaging)
- -40 to 85°C (-40 to 85°C) -40 to 85°C (-40 to 185°F)
Relative humidity
- 5 to 95% (non-condensing)
Altitude
- 2000 m
Standards and certifications
Free fall
- IEC 60068-2-32
EMC
- EN 55032/35
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
- IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-6 CS: 10 V
- IEC 61000-4-8 PFMF
Environmental tests
- IEC 60068-2-1, EN 50155
- IEC 60068-2-14, EN 50155
- IEC 60068-2-2, EN 50155
- IEC 60068-2-30, EN 50155
International approval
- RCM
Railway
- EN 50121-4
- EN 50155
Railway fire protection
- EN 45545-2
Safety
- EN 60950-1
- UL 508
Salt spray test
- IEC 60068-2-11, EN 50155
Shock
- IEC 60068-2-27, IEC 61373, EN 50155
Vibration
- IEC 60068-2-64, IEC 61373, EN 50155
Declaration
Environmentally friendly product
- RoHS, CRoHS, WEEE
MTBF
Time
- 3.451,678 hours
Standards
- Telcordia SR332