TCC-100I-T - RS-232 to RS-422485 converter with optical isolation, -40 to 85C operating tempe

Deliverytime: 9 - 11 working days (Mo-Fr) *
186,99 EUR
Key points at a glance:
Product Description
Moxa's serial-to-serial media converters can convert between RS-232, RS-422, and RS-485, which avoids compatibility issues that are often encountered when communicating between different serial interfaces.

RS-232 to RS-422/485 converter with optical isolation, -40 to 85°C operating temperature

Serial Interface
Baudrate
- 50 bps to 921.6 kbps (supports non-standard baudrates)
Connector
- Terminal block
Isolation
- 2 kV (I models)
No. of Ports
- 2
Pull High/Low Resistor for RS-485
- 1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control
- ADDC (automatic data direction control)
Serial Standards
- RS-232
- RS-422
- RS-485
Terminator for RS-485
- N/A, 120 ohms, 120 kilo-ohms

Serial Signals
RS-232
- TxD, RxD, RTS, CTS, GND
RS-422
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w
- Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w
- Data+, Data-, GND

Power Parameters
Input Current
- 150 mA @ 12 to 48 VDC
Input Voltage
- 12 to 48 VDC
No. of Power Inputs
- 1
Overload Current Protection
- Supported
Power Connector
- Terminal block (for DC models)

Physical Characteristics
Housing
- Metal
Dimensions
- 67 x 100.4 x 22 mm (2.64 x 3.93 x 0.87 in)
IP Rating
- IP30
Weight
- 148 g (0.33 lb)
Installation
- DIN-rail mounting (with optional kit)
- Wall mounting

Environmental Limits
Operating Temperature
- -40 to 85°C (-40 to 185°F)
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
- 5 to 95% (non-condensing)

Standards and Certifications
EMC
- EN 55032/35
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
- IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
- IEC 61000-4-5 Surge: Power: 1 kV
- IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
- IEC 61000-4-8 PFMF
Environmental Testing
- IEC 60068-2-1
- IEC 60068-2-2
- IEC 60068-2-3
Safety
- UL 60950-1
Vibration
- IEC 60068-2-6

MTBF
Time
- 3,017,857 hrs
Standards
- Telcordia (Bellcore), GB
This website uses cookies to ensure you get the best user experience. Privacy Policy