PWR-103-LV-VB-I - Power supply module for PoE models in the EDS-4000 series
Moxa's managed Layer 2 switches are characterised by industrial-grade reliability, network redundancy and security features based on the IEC 62443 standard. We offer robust, industry-specific products with multiple industry certifications, such as parts of the EN 50155 standard for railway applications, IEC 61850-3 for energy automation systems and NEMA TS2 for intelligent transport systems.
Power supply module for PoE models of the EDS-4000/G4000 series with 12/24/48 VDC redundant dual inputs, current isolation, 12 to 57 VDC operating voltage (>52 VDC recommended for PoE+ output)
Power supply parameters
Note
- The device model name and the power supply parameters of the EDS-4000/G4000 series are determined by the installed PWR-100 power supply module.
- PWR-100-LV: -LV/-LV-T models
- PWR-105-HV-I: -HV/-HV-T models
- PWR-101-LV-BP-I: -LVA/-LVA-T models (PoE support)
- PWR-103-LV-VB-I: -LVB/-LVB-T models (PoE support)
- Example: EDS-G4008-T + PWR-100-LV = EDS-G4008-LV-T, EDS-G4008-T + PWR-105-HV-I = EDS-G4008-HVT
- If you install a different power supply module, observe the specifications of the corresponding model. For example, if you replace the power module of the EDS-G4008-LV-T with the PWR-105-HV-I, observe the specifications of the EDS-G4008-HV-T.
- Power over Ethernet: Only the models EDS-4008-4P-2GT-2GS(-T), EDS-4012-8P-4GS(-T) and EDS-G4012-8P-4QGS(-T) support PoE. If a PoE-capable module of the PWR-100 series (PWR-101-LV-BP-I, PWR-103-LV-VB-I) is installed in a non-PoE-capable model of the EDS-4000/G4000 series, the PoE functionality is not available.
Connection
- 2 detachable 4-contact terminal block(s)
Input voltage
- 12/24/48 VDC
Operating voltage
- 12 to 57 VDC (> 52 VDC for PoE+ output recommended)
Input current
- 12/48 VDC, 7.46/4.27 A or 24 VDC, 7.26 A
Number of current inputs
- Redundant dual inputs
Inrush current (max.)
- Max. 0.8 A @ 48 VDC (0.1 to 1 ms)
Overload current protection
- Supports
Reverse polarity protection
- Supports
Physical properties
Dimensions
- 103 x 98 x 39.9 mm (4.06 x 3.86 x 1.57 in)
Weight
- 244 g (0.54 lb)
Environmental conditions
Operating temperature
- The operating temperature depends on the EDS-4000/G4000 switch in which the module is installed. For further information, please refer to the relevant data sheet for the EDS-4000/G4000 series.
Storage temperature- -40 to 85°C (-40 to 185°F)
Relative humidity
- 5 to 95% (non-condensing)
Standards and certifications
Safety
- EN 62368-1 (LVD)
EMI
- FCC Part 15 Subpart B Class A
EMC
- EN 55032/35
- EN 61000-6-2/-6-4
EMS
- EN 61000-4-2 (ESD) Level 4
- EN 61000-4-3 (RS) Level 3
- EN 61000-4-4 (EFT) Level 4
- EN 61000-4-5 (Surge) Level 4
- EN 61000-4-6 (CS) Level 3
- EN 61000-4-8 Level 4
Vibration
- ISTA 1A
Manufacturer information
VARIA System GmbH
Dr.-Salvador-Allende-Straße 191
09119 Chemnitz
DE - Deutschland
E-Mail: info@varia.org
Person responsible for the EU
VARIA System GmbH
Dr.-Salvador-Allende-Straße 191
09119 Chemnitz
DE - Deutschland
E-Mail: info@varia.org