TN-5308-LV-CT - Unmanaged Ethernet switch with 8 10/100BaseT(X) M12 ports, 12 to 48 VDC

Deliverytime: 9 - 11 working days (Mo-Fr) *
584,55 EUR
Key points at a glance:
Product Description

Moxa is an IRIS-certified company that offers an extensive portfolio of robust Ethernet switches that fulfil the mandatory sections of the EN 50155 standard. These products are used in many railway and metro systems around the world. With our innovative solutions and technologies, we help train builders to increase the safety and efficiency of the entire transport system and achieve significant cost and time savings in the operation and maintenance of railway vehicles.

Unmanaged Ethernet switch with 8 10/100BaseT(X) M12 ports, 12 to 48 VDC, -25 to 60°C operating temperature, conformal coating

Ethernet interface
10/100BaseT(X) ports (M12 D-coded 4-pin socket)
- 8
standards
- IEEE 802.3 for 10BaseT
- IEEE 802.3u for 100BaseT(X)
- IEEE 802.3x for flow control

Performance parameters
Input current
- 0.19 A @ 12 VDC, 0.10 A @ 24 VDC, 0.054 A @ 48 VDC
Input voltage
- 12 to 48 VDC
No. Current inputs
- 1
Operating voltage
- 8.4 to 60 VDC
Power connection
- M12 A-coded plug

Physical properties
Housing
- metal
Protection class
- IP40
Dimensions
- 60 x 216.6 x 36.1 mm (2.36 x 8.53 x 1.42 in)
Weight
- Packed: 485 g (1.07 lb)
Installation
- DIN rail mounting (with optional kit)
Wall mounting
- Protection
- PCB conformal coating

Environmental conditions
Operating temperature
- -25 to 60°C (-13 to 140°F)
Storage temperature (including packaging)
- -40 to 85°C (-40 to 85°C) -40 to 85°C (-40 to 185°F)
Relative humidity
- 5 to 95% (non-condensing)
Altitude
- 2000 m

Standards and certifications
Free fall
- IEC 60068-2-32
EMC
- EN 55032/35
EMI
- CISPR 32, FCC Part 15B Class A
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
- IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
- IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
- IEC 61000-4-6 CS: 10 V
- IEC 61000-4-8 PFMF
Environmental tests
- IEC 60068-2-1, EN 50155
- IEC 60068-2-14, EN 50155
- IEC 60068-2-2, EN 50155
- IEC 60068-2-30, EN 50155
International approval
- RCM
Railway
- EN 50121-4
- EN 50155
Railway fire protection
- EN 45545-2
Safety
- EN 60950-1
- UL 508
Salt spray test
- IEC 60068-2-11, EN 50155
Shock
- IEC 60068-2-27, IEC 61373, EN 50155
Vibration
- IEC 60068-2-64, IEC 61373, EN 50155

Declaration
Environmentally friendly product
- RoHS, CRoHS, WEEE

MTBF
Time
- 2.804,342 hours
Standards
- Telcordia SR332