Product Description
Moxa's industrial-grade serial-to-fiber optic converters can convert RS-232/422/485 to optical fiber, which provides users with an easy and reliable way to communicate with their serial devices.
Industrial RS-232/422/485 to multi-mode fiber converter, ST connector, 2 kV isolation, -40 to 85°C operating temperature
Serial Interface
- No. of Ports 2
- Serial Standards
RS-232
RS-422
RS-485
- Baudrate 50 bps to 921.6 kbps (supports non-standard baudrates)
- Flow Control ADDC (automatic data direction control) for RS-485
- Connector
5-pin terminal block
Multi-mode ST connector
- Isolation 2 kV (I models)
- Pull High/Low Resistor for RS-485 150 kilo-ohm, 10 kilo-ohm, 4.7 kilo-ohm, 3.3 kilo-ohm, 1 kilo-ohm, 909 ohm, 822 ohm, 770 ohm, 500 ohm, 485 ohm
- RS-485 Data Direction Control ADDC (automatic data direction control)
- Terminator for RS-485 N/A, 120 ohms, 120 kilo-ohms
Serial Signals
- RS-232 TxD, RxD, GND
- RS-422 Tx+, Tx-, Rx+, Rx-, GND
- RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
- RS-485-2w Data+, Data-, GND
Power Parameters
- Input Current 300 mA @ 12 to 48 VDC
- Input Voltage 12 to 48 VDC
- No. of Power Inputs 1
- Overload Current Protection Supported
- Power Connector Terminal block
- Power Consumption 300 mA @ 12 to 48 VDC
Physical Characteristics
- Housing Metal
- IP Rating IP30
- Dimensions 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in)
- Weight 330 g (0.73 lb)
- Installation DIN-rail mounting
Environmental Limits
- Operating Temperature -40 to 85°C (-40 to 185°F)
- Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity 5 to 95% (non-condensing)
Standards and Certifications
- EMC EN 55032/35
- EMI CISPR 32, FCC Part 15B Class A
- EMS
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 1 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
IEC 61000-4-8 PFMF
- Environmental Testing
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
- Safety UL 61010-2-201
- Vibration IEC 60068-2-6
- Hazardous Locations
UL/cUL Class I Division 2 Groups A/B/C/D
ATEX Zone 2
MTBF
- Time 792,085 hrs
- Standards Telcordia (Bellcore), GB