EDS-405A-EIP - Entry-level managed Ethernet switch with 5 10100BaseT(X) ports
Layer 2 Managed Switches
Moxa's Layer 2 managed switches feature industrial-grade reliability, network redundancy, and security features based on the IEC 62443 standard. We offer toughened, industry-specific products with multiple industry certifications, such as parts of the EN 50155 standard for rail applications, IEC 61850-3 for power automation systems, and NEMA TS2 for intelligent transportation systems.
EDS-405A-EIP
EDS-405A Series
Entry-level managed Ethernet switch with 5 10/100BaseT(X) ports, EtherNet/IP enabled, 0 to 60°C operating temperature
- Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector)
5
Auto negotiation speed
Full/Half duplex mode
Auto MDI/MDI-X connection
Optical Fiber
Read more
- Standards
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
IEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for Rapid Spanning Tree Protocol
- Ethernet Software Features
Filter
802.1Q VLAN
GMRP
GVRP
IGMP v1/v2
Port-based VLAN
Industrial Protocols
EtherNet/IP (enabled by default)
Modbus TCP
Management
Back Pressure Flow Control
BOOTP
DHCP Option 66/67/82
DHCP Server/Client
Flow control
IPv4/IPv6
LLDP
Port Mirror
RARP
RMON
SMTP
SNMP Inform
SNMPv1/v2c/v3
Syslog
Telnet
TFTP
MIB
Bridge MIB
Ethernet-like MIB
MIB-II
P-BRIDGE MIB
RMON MIB Groups 1, 2, 3, 9
RSTP MIB
Redundancy Protocols
RSTP
STP
Turbo Chain
Turbo Ring v1/v2
Time Management
NTP Server/Client
SNTP
- Switch Properties
IGMP Groups
256
MAC Table Size
2 K
Max. No. of VLANs
64
Packet Buffer Size
1 Mbits
Priority Queues
4
VLAN ID Range
VID 1 to 4094
- Serial Interface
Console Port
RS-232 (TxD, RxD, GND), 10-pin RJ45 (115200, n, 8, 1)
- DIP Switch Configuration
Ethernet Interface
Turbo Ring, Master, Coupler, Reserve
- Input/Output Interface
Alarm Contact Channels
Relay output with current carrying capacity of 1 A @ 24 VDC
- Power Parameters
Input Voltage
12/24/48 VDC
Redundant dual inputs
Operating Voltage
9.6 to 60 VDC
Input Current
0.594 A @ 12 VDC
0.286 A @ 24 VDC
0.154 A @ 48 VDC
Overload Current Protection
Supported
Reverse Polarity Protection
Supported
Connection
1 removable 6-contact terminal block(s)
- Physical Characteristics
Housing
Metal
IP Rating
IP30
Dimensions
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight
650 g (1.44 lb)
Installation
DIN-rail mounting
Wall mounting (with optional kit)
- Environmental Limits
Operating Temperature
-10 to 60°C (14 to 140°F)
Storage Temperature (package included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity
5 to 95% (non-condensing)
- Standards and Certifications
Safety
UL 508
UL 60950-1
EN 62368-1
EMC
EN 55032/35
EMI
CISPR 32, FCC Part 15B Class A
EMS
IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
Hazardous Locations
ATEX
Class I Division 2
Railway
EN 50121-4
Traffic Control
NEMA TS2
Vibration
IEC 60068-2-6
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-31
Maritime
DNV
LR
- MTBF
Time
1,547,941 hrs
Standards
Telcordia (Bellcore), GB