The CSM-200 plug-in media converters from Ethernet to fibre optic are designed for the NRack System™. The modules provide media conversion from 10/100BaseT(X) to 100BaseFX (SC/ST connectors) and can be installed in any NRack System™ enclosure.

Ethernet interface
– 10/100BaseT(X) ports (RJ45 connector): 1
– 100BaseFX ports (single-mode SC connector): CSM-200-1218: Single-mode SC connector
– Magnetic insulation protection: 1.5 kV (built-in)
– Standards: IEEE 802.3u for 100BaseT(X) and 100BaseFX
– Fibre optic

Performance parameters
– Input current: 180 mA @ 12 VDC
– Input voltage: 12 VDC
– Overload current protection: Supported
– Power consumption: 180 mA @ 12 VDC

Physical properties
– Dimensions: 86.8 x 124.3 x 21 mm (3.42 x 4.89 x 0.83 in.)
– Weight: 125 g (0.28 lb)

Environmental Conditions
– Operating Temperature: 0 to 55°C (32 to 131°F)
– Storage Temperature (including packaging): -40 to 85°C (-40 to 185°F)
– Ambient relative humidity: 5 to 95% (non-condensing)

Standards and certifications
– EMC: EN 55032/24
– EMI: CISPR 32, FCC Part 15B Class A
– Safety: EN 60950-1, UL 60950-1
– Vibration: IEC 60068-2-6

EMS
– IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
– IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
– IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
– IEC 61000-4-5 Surge: Power: 2 kV(AC), 1 kV(DC)
– IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
– IEC 61000-4-8 PFMF
– IEC 61000-4-11

Environmental testing
– IEC 60068-2-1
– IEC 60068-2-14
– IEC 60068-2-2
– IEC 60068-2-3

MTBF
– Time: 1.454,560 hours
– Standards: Telcordia (Bellcore), GB